Firefighters battle attic fire on Main Street Tucson building


Audio|Source: Tucson Police/Fire Citywide
04:20
Transcript:
This password is 889. Parked your engine out of the way, grab a second line off of engine one, go to the Delta 1 and check for exposure. Command engine 2 copies, come line into the scene, park out of the way, pulling just a line off engine 1 for the delta 1 exposure, check for fire extension and for primary out clear. 3-1 and Engine 81 down to Ops. Out of service. This is that copy. My 899, if you can have the TFC station line. My apologies, dispatch, 889. Can you please repeat? My apologies, I think I called you the wrong resonator in the beginning. If you could head to Station 16. The primary search and fire control on the main fire occupancy, Alpha-sized ladders going for a roof report. Engine 2 is on the Delta 1 exposure. If there's nothing else, provide me with the camera port. That's the front of Battalion 1. Engine 1 has a primary all-clear on fire control and main fire occupancy. No need. Battalion 1 copies. Great alarm from Battalion 1. Battalion 1 will now have Main Street command. Continue to balance. Battalion 1 from Alarm, I copy. Battalion 1 is assuming Main Street Command. We're going to be continuing to balance confirming offense strategy. That's affirmative. Command from Agent 2 with prior to traffic. Go ahead with priority traffic engine 2. We have a primary al-clearant-the-delta exposure. We've opened up the attic. We do have an attic fire for applying water. Our need, we could use another company for help. Engine 2 I copy, you have fire in the attic space. You have a primary all clear. When we get another unit, I'll be assigned in with you. Command ladder one prior to traffic. Go ahead, the letter one. Command ladder one. We had a stable roof of no sagging. We've got a firewall on the Bravo side. We were getting some smoke coming from some vents on the roof, so we cut an inspection hole, we've got fire in the attic, but the roof is currently stable. Lighter when I copy, we have fire coming from the inspection hole. Go ahead and exit the roof, secure the utilities, and let me know when you're ready for a raise on it. Lighter one copy, you'll be exiting the roof and securing utilities. We're supposed to the north doors. It's not out of the building yet, but he's starting to walk this way. We did get knocked down. We're pulling sewing, plying water with good effect. Injorn, do you have any needs? No, you have. Command copies, thank you. Command Engine 3, Level 1. Engine 3 from Command. Let us spot your apparatus out of the way. Pull an additional line off of Engine 1 and go join Engine 2 in the Delta 1 exposure to fight the attic fire. Copy, we're pulling an additional line and joining engine 2 and the Delta 1 exposure.
Disclaimer:
This was transcribed by AI and may contain errors. Please verify the information independently.
Location mentioned:
Main St, Tucson, AZ 85705
Correct
Incorrect